    High-temperature insulated wire is not a one-size-fits-all product. With regards to the application, different facets will go into selecting the right type of wire to get the done right. In this post, we’ll take particular notice at what these factors are and how they’re able to help with choosing the ultimate high-temperature insulated wire to your specific situation.

    Factor #1: Concept of Electrical Requirements – Operating voltage, conductor temperature rating and current-carrying capacity (aka ampacity) must all be met in choosing high-temperature insulated wire. Such wiring is labeled which has a temperature rating, which can be determined by a variety of ambient heat and current-generated heat. Ambient heat stems from the approval being performed whereas current-generated heat is calculated by matching conductor material and diameter to service amperage. You will need to observe that due to the difficulty in pinning down exact current-carrying capacity, product designers often specify higher capacity conductors than theoretical calculations would indicate.

    Factor #2: Environmental Conditions – What is happening in the wire is not only consideration in relation to choosing the right high-temperature insulated wire. External environmental factors may also be important. That is because they can use a damaging influence on both wire’s insulation and its interior circuitry. Ambient heat, moisture, abrasion, thermal stability, chemical attach, mechanical abuse, low temperature, flame resistance, easy stripping terminating and routing are typical environmental conditions have to be paid for when selecting high-temperature insulated wire. Some factors are discussed in depth further on in this article.

    Factor #3: Conductor Material Type – The wire’s conductor material determines the most temperature it can withstand. Situations which need the wire to have the best of temperatures, like high-rise alarms in the case of a fire, may well be more reliably served with nickel-coated copper and nickel conductors, because both versions can endure temperatures around 550 degrees Celsius. Copper, nickel-plated and iron conductors conversely can take up under only an upper selection of 200 to 250 degrees Celsius.

    Factor #4: Current-Carrying Capacity or Ampacity – A lot of the environmental conditions talked about above also have an impact on high-temperature insulated wire’s power to carry current. Because of this, they should be weighed into the equation. Ampacity is measured because current a conductor can transport prior to combined temperature of both conductor and insulation rises above a permitted limit.

    Conductor size and material, amperage, ambient temperature and insulation type will all be the cause could be the wire’s ampacity. The conductor’s diameter and mass include the most influential size considerations. The smaller these are, the lower the high-temperature insulated wire’s ampacity. As previously pointed out in the Factor #3 section, a conductor’s material has a strong touching on the amount temperature the wire can withstand and that temperature range varies widely. Likewise, different materials produce wide fluctuations inside the current-carrying capacity of the wire as well.

    Finally, the insulation employed in the wire will determine simply how much heat it dissipates and, in turn, the ampacity. The dissipation problem becomes even more complicated when wire is enclosed inside a tightly confined space, so fire alarms in high-rise ductwork, by way of example, pose additional challenges when looking for high-temperature insulated wire options.